Solar PV System Data Collection and Testing

Introduction

In this activity, we studied two Solar PV systems. We collected technical information from the solar panel data sheet and checked the panel voltage using a digital multimeter. We calculated the total voltage and total power from the number of panels.

Solar PV System 1 – Panasonic Solar

ParameterReading
Total Panels20
Single Panel Voltage37.3 V
Panel Efficiency16.7%
Current20 A
Power of One Panel370 W
Maximum System Voltage1500 V

Calculations

1. Total Voltage

Formula:

Total Voltage = Number of Panels × Voltage of One Panel

= 20 × 37.3

= 746 V

2. Total Power

Formula:

Total Power = Number of Panels × Power of One Panel

= 20 × 370

= 7400 W

= 7.4 kW


Solar PV System 2 – Vikram Solar

ParameterReading
Total Panels6
Single Panel Voltage39 V
Panel Efficiency20%
Current13 A
Power of One Panel545 W
Maximum Panel Voltage41.80 V

Calculations

1. Total Voltage

Formula:

Total Voltage = Number of Panels × Voltage of One Panel

= 6 × 39

= 234 V

2. Total Power

Formula:

Total Power = Number of Panels × Power of One Panel

= 6 × 545

= 3270 W

= 3.27 kW

Practical Testing

We used a digital multimeter to check the DC voltage of the solar panels. The red probe was connected to the positive terminal and the black probe to the negative terminal. We compared the multimeter reading with the data sheet value. The voltage can change according to sunlight and weather conditions.