AIM : to make a cover for the inverter
REQUIREMENTS : re-bar of length 21.81 ft , L-angle of length 7 ft , welding rods
TOOLS REQUIRED : hand grinder <, cutting wheel , grinding wheel , welding machine , measuring tape, marker
WHY I CHOOSE THIS PROJECT ; the inverter in the grey water bubbler plant had no protection against rain water , water seeping through below in rainy season , and its security was compromised
PROCEDURE: 1) measure the length between two legs of the cupboard cut L-angle of the appropriate size in our case it was 48 cm and other was 41 cm
2) cut the L-angle of appropriate length with the chop-saw and keep them aside
3) measure the rebar as the protection and cut it in our case it was 41 cm 10 nos and other 48 cm 5 nos rebars
4) weld the L-angles together onto the body using right angles and set squares
5) weld them together using welding machine set to 200A of current
6) align and weld the re-bars together in our case it was 15 re-bars
7) after welding grind the welding points and give finishing\
COSTING :
SRNO | MATERIAL NAME | SIZE | RATE | TOTAL MATERIAL USEDX | TOTAL COST |
1 | L-angle | 48*5 | 3.14FT | 15rs/ft | 47.1 |
2 | L-angle | 41*3 | 4.03 | 15rs/ft | 60.45 |
3 | re-bar | 52*5 | 21.81 | 50rs/kg | 69.454 |
4 | TOTAL MATERIAL COST | 177 | |||
5 | ELETRICITY COST | 17.7 | |||
6 | LABOUR COST | 44.25 | |||
7 | DEPRTESSION | 8.25 | |||
8 | TOTAL MATERIAL COST | 247 | |||
9 |
Modifying cupboard
Rebar
(21.81 ft )
L- angle
(7ft)
Material collection done hand grinder
Rebar cutting wheel
(52*5) grinding wheel
(40.5*10)
L-angle cut
(48cm *2)
(41cm* 3)
Material cutting done
Welding arc welder
Wrlding rods
Safety helmet
Safety glasses
Safety gloves
Safety shoes